8" Cast Iron Double Check Detector Assembly Backflow Preventer, OSY Shutoffs, Cu Ft Meter, 3/4" Bypass, NYC Approved Meter, Pre-drilled Bolts, ArmorTek Coating

8" Cast Iron Double Check Detector Assembly Backflow Preventer, OSY Shutoffs, Cu Ft Meter, 3/4" Bypass, NYC Approved Meter, Pre-drilled Bolts, ArmorTek Coating

8" Cast Iron Double Check Detector Assembly Backflow Preventer, OSY Shutoffs, Cu Ft Meter, 3/4" Bypass, NYC Approved Meter, Pre-drilled Bolts, ArmorTek Coating

ERP #WATT-88007514

MFR #88007514

UPC098268223910

Log In or Register for Product Pricing & Availability
Description

This 8" double check valve backflow preventer assembly is designed to prevent the reverse flow of contaminated water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure. It is ideal for protection at cross-connections identified as non-health hazard applications and contaminants found at the service line. This assembly consists of a fused epoxy coated cast iron body using ArmorTek(TM) coating technology for advanced corrosion resistance construction, OSY resilient seated gate valves, test cocks, and a modular check design with center stem guide. The captured spring is accessible through a bolted cover plate. This NYC version comes with an NYCDEP approved CFM meter and four sets of 304SS bolts/nuts with a 1/4" hole drilled axially through the bolt.The coating on this backflow assembly uses ArmorTek technology to resist corrosion due to microbial induced corrosion (MIC) or exposed metal substrate.

  • Utilizes advanced ArmorTek coating technology to resist corrosion of internals
  • The valve body shall utilize a coating system with built in electrochemical corrosion inhibitor and microbial inhibitor
  • Modular check assemblies
  • Detector bypass with NYCDEP approved meter
  • Drilled bolts to eliminate flange drilling